RGB Spectrum 201 Benutzerhandbuch

Seite von 167
C O M M U N I C A T I O N S   S E T U P
Ethernet control
350-8697
DGy Model 201 User Guide
144
. . . . .
IP ADDRESS SETUP 
. . . . . . . . . 
VIA ETHERNET 
DGy 201’s IP address can be set directly via Ethernet, using a Telnet 
session that enables you to remotely log into DGy 201 from a computer. 
This procedure is not required if you have already set the IP address 
using the method described above, in the “
” section of this chapter (page 143). 
Use the following procedure to set up the IP address with a Telnet 
session:
1.
Use an Ethernet crossover cable to connect directly between 
the DGy 201’s Ethernet port the network port of your PC.
Note
For this procedure, the direct connection method is 
recommended over the network method. This avoids 
potential conflicts between DGy 201’s default IP 
address and your network.
2. 
From the Start menu at the bottom of your Windows desktop 
select “Run...” 
3. 
In the “Open” dialog box type “cmd” as shown in the following 
figure.
4. 
Click on the OK button to open the Windows command window.
5. 
At the command prompt in the command window type:
telnet <ipaddress> 8000
where <ipaddress> represents DGy 201’s current IP address. 
S
Example: If you have not changed DGy 201’s default IP 
address, it should be set to:
192.168.1.200
Using the default IP address shown above, in the command line 
window, type:
telnet 192.168.1.200 8000
... and press Enter.