Clarity WN=5230-S Benutzerhandbuch
WN-5230-S VideoWall User’s Guide
103
Function
RS-232 COMMANDS
Inc
Dec
RS-232
DATA
Get
Set
Comments
Auto re-strike Controls
System status request
S0$
Bit 7:
Lamp status (1=on; 0=off)
Bit 6:
Lamp failure (1=fail; 0=OK)
Bit 5:
Not used
Bit 4:
Not used
Bit 3:
System state: bit 3
Bit 2:
System state: bit 2
Bit 1:
System state: bit 1
Bit 0:
System state: bit 0
The system state can have the
following values
0000 – Lockout state
0001 – Standby state
0010 – Run state
0011 – Force on ignition state
0100 – Manual ignition state
0101 – Ignition state
0110 – Re-strike state
All others are not used.
Enable / Disable Auto re-strike
LF1
LF0
LF*
LF1 – auto re-strike active
LF0 – auto re-strike inactive
LF0 – auto re-strike inactive
Test Signal Controls
Test Signal Disable (Pass Video)
TSD
TS*
TSD removes test signal and allows
video to show. 0 = off,
1 = White, 2 = Black, 3 = Gray,
4 = Red, 5 = Green, 6 = Blue,
7 = Geometry red, 8 = Gmtry cyan,
9 = Gmtry black, 10 = Gray Ramp
video to show. 0 = off,
1 = White, 2 = Black, 3 = Gray,
4 = Red, 5 = Green, 6 = Blue,
7 = Geometry red, 8 = Gmtry cyan,
9 = Gmtry black, 10 = Gray Ramp
Test Signal - White Field
WHT
Test Signal - Black Field
BLK
Test Signal - 50% Gray Field
GRY
Test Signal - Red Field
RED
Test Signal - Green Field
GRN
Test Signal - Blue Field
BLU
Test Signal - Geometry red
GE1
Test Signal - Geometry cyan
GE2
Test Signal - Geometry black
GE3
Test Signal - Gray ramp
GE4
Test Signal -
TS*
0 = off, 1 = on
Test Signal - Data Red
TR#
Set test signal red level 0-255
Test Signal - Data Green
TG#
Set test signal green level 0-255
Test Signal - Data Blue
TB#
Set test signal blue level 0-255
System Monitor
Ping
PNG
Verifies that a cube is at an address
Product ID
P00
Gets the product ID (hex)
In the About menu, the project
number is 573-xxyy-zz. The xx value
is returned as a hex number.
In the About menu, the project
number is 573-xxyy-zz. The xx value
is returned as a hex number.
Version ID
VER
Get software version ID
0x01 – Rev A
0x02 – Rev B
0x03 – Rev C
etc.
0x01 – Rev A
0x02 – Rev B
0x03 – Rev C
etc.
Big Picture Controls
Wall Horizontal Size
WXn
WX$
n=1..4
Wall Vertical Size
Wyn
WY$
n=1..4
Wall Mode Calculate
WMC
Wall Mode On/Off
WM1
WM0
WM*
WM* returns WM1 or WM0
Protocol Control (1)
Received Valid Command
ACK
Command successfully executed.
Received Invalid Command
NAK
Command error on execution.
Unknown command
UNK
Unknown command.