Clarity WN=5230-S 用户手册

下载
页码 122
 
 
WN-5230-S VideoWall User’s Guide 
 
 
103 
 
Function 
 
RS-232 COMMANDS 
Inc  
Dec 
RS-232 
DATA 
  Get 
  Set 
 
Comments 
Auto re-strike Controls 
 
 
 
 
 
System status request 
 
 
S0$ 
 
Bit 7: 
Lamp status (1=on; 0=off) 
Bit 6: 
Lamp failure (1=fail; 0=OK) 
Bit 5: 
Not used 
Bit 4:  
Not used 
Bit 3:  
System state: bit 3 
Bit 2: 
System state: bit 2 
Bit 1: 
System state: bit 1 
Bit 0: 
System state: bit 0 
 
The system state can have the 
following values 
0000 – Lockout state 
0001 – Standby state 
0010 – Run state 
0011 – Force on ignition state 
0100 – Manual ignition state 
0101 – Ignition state 
0110 – Re-strike state 
All others are not used. 
Enable / Disable Auto re-strike 
LF1 
LF0 
LF* 
 
LF1 – auto re-strike active 
LF0 – auto re-strike inactive 
Test Signal Controls 
 
 
 
 
 
Test Signal Disable (Pass Video) 
TSD 
 
TS* 
 
TSD removes test signal and allows 
video to show. 0 = off,  
1 = White, 2 = Black, 3 = Gray,   
4 = Red, 5 = Green, 6 = Blue,   
7 = Geometry red, 8 = Gmtry cyan,  
9 = Gmtry black, 10 = Gray Ramp 
Test Signal - White Field  
WHT 
 
 
 
 
Test Signal - Black Field 
BLK 
 
 
 
 
Test Signal - 50% Gray Field 
GRY 
 
 
 
 
Test Signal - Red Field 
RED 
 
 
 
 
Test Signal - Green Field 
GRN 
 
 
 
 
Test Signal - Blue Field 
BLU 
 
 
 
 
Test Signal - Geometry red 
GE1 
 
 
 
 
Test Signal - Geometry cyan 
GE2 
 
 
 
 
Test Signal - Geometry black 
GE3 
 
 
 
 
Test Signal - Gray ramp 
GE4 
 
 
 
 
 
 
 
 
 
 
Test Signal -  
 
 
TS* 
 
0 = off, 1 = on 
Test Signal - Data Red 
 
 
 
TR# 
Set test signal red level 0-255 
Test Signal - Data Green 
 
 
 
TG# 
Set test signal green level 0-255 
Test Signal - Data Blue 
 
 
 
TB# 
Set test signal blue level 0-255 
System Monitor 
 
 
 
 
 
Ping 
 
 
PNG 
 
Verifies that a cube is at an address 
Product ID 
 
 
P00 
 
Gets the product ID (hex) 
In the About menu, the project 
number is 573-xxyy-zz. The xx value 
is returned as a hex number.  
Version ID 
 
 
VER 
 
Get software version ID 
0x01 – Rev A 
0x02 – Rev B 
0x03 – Rev C 
etc. 
Big Picture Controls 
 
 
 
 
 
Wall Horizontal Size 
 
 
WXn 
WX$ 
n=1..4 
Wall Vertical Size 
 
 
Wyn 
WY$ 
n=1..4 
Wall Mode Calculate 
WMC 
 
 
 
 
Wall Mode On/Off 
WM1 
WM0 
WM* 
 
WM* returns WM1 or WM0 
Protocol Control (1) 
 
 
 
 
 
Received Valid Command 
ACK 
 
 
 
Command successfully executed. 
Received Invalid Command 
NAK 
 
 
 
Command error on execution. 
Unknown command 
UNK 
 
 
 
Unknown command.