Section 4. System Startup
4.1 
Handheld Remote Programming
4.1.1.  Basic Programming Menu
To set a particular piece of equipment to turn on 
and off at predetermined times, highlight MENU 
and press SELECT (see Figure 23). Highlight 
PROGRAM and press SELECT. Use the UP or 
DOWN buttons to highlight the equipment (for 
example, Filter Pump) then press SELECT. Follow 
the on-screen prompts. Use the UP or DOWN 
buttons to pick each number, starting with ON 
hours, press SE LECT to enter and move on to the 
next item to change, including picking what day(s) 
the program will run. If you make a mistake, use 
the BACK button to return to a number. If the 
program is already en tered, highlight CHANGE 
PROGRAM and step through to the entry that 
should be cor rect ed.
3. 
Use the UP and DOWN buttons to highlight 
the desired RF channel. Then press 
SELECT.
4. 
When the RF channel is selected, the 
following message appears on the PDA 
display screen:
Set slide switch on J-Box PCB to the 
LEARN MODE.
5. 
At the PCB in the Transceiver J-box, slide 
the Learn Switch to LEARN (ON). See 
Figure 22.
SET RF CHANNEL
RF CHANNEL:   1
Use ARROW  KEYS
to set the 
RF CHANNEL.
Press SELECT to
continue.
UP 
Button
DOWN 
Button
SELECT Button
Figure 21.  PDA Handheld Remote Channel Setup 
and Buttons
Figure 23.  PDA Handheld Remote Buttons
BACK
Button
UP 
Button
DOWN 
Button
SELECT
Button
HOT KEY 1
HOT KEY 2
Power ON/OFF
Button
6. 
On the PDA Handheld Remote display 
screen, a prompt will appear with 
instructions to slide the J-box Learn Switch 
out of LEARN (OFF) and to press the J-box 
Reset Switch.
7. 
At the PCB in the Transceiver J-box, slide 
the Learn Switch out of LEARN and press 
the Reset Switch. The Red and Green LEDs 
on the J-box will blink simultaneously (see 
Figure 22).
Figure 22.  Tranceiver J-box PCB Learn Switch
Transceiver 
PCB
Reset Switch
Learn 
Switch
Shown 
in Learn 
Mode 
- Switch 
Position 
On.
Green 
LED
Red 
LED