12 Volt Out Supply
This internal power supply can be used to power external 
devices &/or to initiate specific functions (see Pushbutton 
operation and Figure 25).
1.
Connect one lead to 12 VOLT GROUND (terminal #9).
2.
Connect one lead to 12 VOLTS OUT (terminal #10).
24 Volt Out Supply
This internal power supply can be used to power external 
devices & remote controllers (see Figure 26).
1.
Connect one lead to 24 VOLT COMMON (terminal #2).
2.
Connect one lead to 24 VOLTS OUT (terminal #1).
Two Dry Contact Closures
NOTE:  Dry contacts are rated for 1 Amp @ 24 volts.
These contacts can be used to complete circuits to external 
devices (see Figure 27 and Figure 28).
1.
Connect one lead to terminal #17 (extend limit common).
2.
Connect one lead to terminal #16 (closes when unit 
reaches full extension).
3.
Connect one lead to terminal #19 (retract limit common).
4.
Connect one lead to terminal #18 (closes when unit is 
fully retracted).
Low Voltage Sensing
1.
Connect positive lead (5 - 30 volts AC/DC) to terminal #7 
and ground of switching device to terminal #8 (see 
Figure 29). Unit extends when voltage is sensed, retracts 
when voltage ceases.
Example using internal 12 volt DC supply (Figure 30):
Figure 25.  12 Volts
Figure 24.  26 Volts
Figure 27.  Extend Dry Contacts
Figure 28.  Retract Dry Contacts
Figure 29.  Low Voltage Sensing