Toshiba LF410/LF602 User Manual
LF410/LF600 LF410/LF602
14
Table 3. Specification Code (Wafer type detector LF410 Series)
Detector category
Model Specification
Code
Normal type
Ex. type
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Description
Gr.-A Gr.-B Gr.-C
Gr.-D
L
F 4 1 0 Normal
specification
type
√
√
L
F 4 1 4 Hazardous
location
certification
type
(Note
1)
√
√
Meter size
D
15mm (½")
√
√
E
25mm (1")
√
√
F
40mm (1½")
√
√
G
50mm (2")
√
√
H
80mm (3")
√
√
J
100mm (4")
√
√
K
150mm (6")
√
√
L
200mm (8")
√
√
Mounting Style
L Detector/Converter
combined
type
(LF410/LF600)
√
√
M Detector/Converter
separate
type
(LF410/LF602)
√
√
P
Detector/Converter combined type with PED (LF410/LF600) (Note 6)
√
√
Q
Detector/Converter separate type with PED (LF410/LF602) (Note 6)
√
√
FM and CSA Class - I Division 2 type (Note 1)
A Detector/Converter
combined
type
(LF414/LF600)
√
√
B Detector/Converter
separate
type
(LF414/LF602)
√
√
Connection
flange
standard
(Note
2)
C
ANSI 150
D
ANSI 300
E
BS PN 10
F
BS PN 16
G DIN
PN
10
H DIN
PN
16
J
JIS 10K
K
JIS 16K
L
JIS 20K
Z
other
–
–
Electrode
Material
(Note
6)
B 316L
stainless
steel
C Ti
(titanium)
D Pt-Ir
(platinum/iridium)
E
Ta (tantalum)
F Hastelloy
C
(Equivalent)
Z
other
–
–
Lining Material (Note 6)
A Alkali-resistant
ceramic
(Note
3)
–
–
B Acid-resistant
ceramic
(Note
3)
–
–
C
Teflon PFA
Grounding
Ring
Material
(Note
6)
C 316
stainless
steel
D
316L stainless steel
E Ti
(titanium)
F
Ta (tantalum)
G Pt-Ir
(platinum/iridium)
H Hastelloy
C
(Equivalent)
Z
other
–
–
Flow
and
calibration
velocity
range
A
0.3
to
10
m/s
(standard
range
calibration)
B
0.3
to
10
m/s
(specified
range
calibration)
C
0.1
to
10
m/s
(specified
range
calibration)
Excitation
and
Signal
Cables
A
not provided
B 30m
cable,
provided
(Note
4)
C other
lengths,
provided
(Note
4)
Coating
A
no coating
–
–
B phthalic
acid
resin
coating
pearl-gray
colored
(Note
5)
C black
tar
epoxy
resin
0.3
mm
D black
tar
epoxy
resin
0.5
mm
E
Black tar epoxy resin 0.5 mm for submersible type (Note 7)
Size code explanation: √ :Object : Standard : Option
–
: Not available
Note1: Cable glands are not provided. Refer to the part of “Cable connection port” at detector and converter.
Note2: Same shape of flange standard among ANSI 150, ANSI 300, BS10, BS16, DIN10, DIN16, JIS10K, JIS16K, and JIS20K.
Note3: The type of material used is alumina ceramic, this is suitable for both acid and alkali liquids.
Note2: Same shape of flange standard among ANSI 150, ANSI 300, BS10, BS16, DIN10, DIN16, JIS10K, JIS16K, and JIS20K.
Note3: The type of material used is alumina ceramic, this is suitable for both acid and alkali liquids.
This ceramic lining and the electrodes are held with seals, there are two types, one for acids, and the other for alkalis.
Note4: Separate type detector only. Specifyng the code “C”, indicate the length of cables from 1 to 300m in 1 meter increments.
Note5: Phthalic acid resin coating is standard for the flowmeter with meter size 15mm(1/2”), 150mm(6”), and 200mm(8”).
Note6: Consult Toshiba before ordering when choose materials at the wetting parts.
Note7: Ceramic lining only. (Teflon PFA lining is not available.)
Note8: Check the Table 2 whether your chosen meter size meets this directive or not when the meter is shipped to EU. If yes, need to choose this code.
Note5: Phthalic acid resin coating is standard for the flowmeter with meter size 15mm(1/2”), 150mm(6”), and 200mm(8”).
Note6: Consult Toshiba before ordering when choose materials at the wetting parts.
Note7: Ceramic lining only. (Teflon PFA lining is not available.)
Note8: Check the Table 2 whether your chosen meter size meets this directive or not when the meter is shipped to EU. If yes, need to choose this code.