4-12
SPAN FAIL
The span value, set with the local span adjustment button, exceeds the 
maximum range down allowed for a particular range, or the pressure sensed 
by the transmitter exceeds the sensor limits.
KEYS DISABL
This message appears during reranging with the integral zero and span 
buttons and indicates that the transmitter local zero and span adjustments 
have been disabled. The adjustments have been disabled by software 
commands from the HART Communicator or AMS. Keys are not detected 
when write protect jumper is active. See “Security (Write Protect)” on 
page 2-5 for information on the sof
tware lockout.
STUCK KEY
The zero or span button is stuck in the depressed state or pushed too long.