Base Enclosure Security Seals
Section 3: Electrical installation
Daniel 3812 Liquid Ultrasonic Flow Meter Installation Manual
May 2015
3-9000-765 Rev H
3.7.2
Base Enclosure Security Seals
Use the following instructions to install the security seal wire on the Base Enclosure.
Procedure
1.
Install security wire seal into and through two of the four the holes in the socket head 
screws on the Base Enclosure cover (maximum wire diameter .078 inch; 2.0mm). 
Figure 3-10  Base Enclosure security seals 
2.
Position the wire to prevent counterclockwise rotation of the screws when the seal wire 
is taut.
3.
Twist and adjust wire removing all slack and seal.
4.
Cut wire ends to remove excess wire.
5.
This completes Base Enclosure security seal installation procedure.
A.
A.  Base Enclosure
B.  Security wire seals 
B.