Monitor problems
Symptom
Cause
Remedy
Data is not 
superimposed on the 
monitor screen.
The CHARA. DISPLAY menu item is 
set to OFF.
Set the CHARA. DISPLAY menu item 
 to ON.
The monitor is not connected to the 
B
−Y/CPST (SUPER) connector of this 
unit.
Connect the monitor to the B
−Y/CPST (SUPER) connector. 
(You must make this connection to display any type of text on 
the monitor.)
The image on the 
monitor screen is too 
bright.
The 75 
Ω termination switch for video 
input on the monitor is in the OFF 
position, or a 75 
Ω terminator is not 
fitted to its video input connector.
Set the 75 
Ω termination switch to ON or connect a 
terminator.
The image on the 
monitor screen is too 
dark. 
In a video signal loop-through 
connection of video monitors, 75 
Ω 
termination switches for video input on 
monitors other than the loop-end 
monitor are in the ON position.
Set the 75 
Ω termination switches to OFF on all monitors 
other than the loop-end monitor.
The image is too dark 
when recording a 
composite video 
signal.
Audio problem
Symptom
Cause
Remedy
The REC/PB LEVEL 
control knobs do not 
work.
The VAR switch on the front panel is 
set to PRESET.
Set the VAR switch to REC when recording, or set it to PB 
when playing back.
Editing restriction
Symptom
Cause
Execution of video 
editing in insert mode 
erases subcode data 
(user bit data, etc.) 
recorded on tape other 
than time code data.
This phenomenon cannot be avoided with an editing system using this unit as the recorder.