AD-4405 Weighing Indicator
 
F22 = 9 (Check weighing 3:Loss in weight)
F22 = 9 (Check weighing 3:Loss in weight)
F22 = 9 (Check weighing 3:Loss in weight)
F22 = 9 (Check weighing 3:Loss in weight)    
 
 
 
 
 
Output and Condition
Output and Condition
Output and Condition
Output and Condition    
 
 
 
 
  *    Relay OK output can be changed to OVER or UNDER by setting f24. 
 
     Triangle  2 is displayed when Gross 
] Full regardless of the f24 setting. 
 
  OVER/UNDER is judged always and the result is output to the LED and the relay. 
 
 
10.2.2. Simple 
Batch 
The weighing sequences of simple batch (f22 10, 11 or 12) are similar to those of 
Check weighing (f22 7, 8 or 9) respectively. The differences are listed below. 
 
1  Basically ON/OFF of the relay and the LED are reversed. 
2  No judgment other than Zero band and Full before input of the Start signal.   
3  The weighing completion condition is set by f23 2x    and it is effective after Start. 
4  The outputs of Preliminary and Free fall are off from weighing completion to the 
next start. 
5  Weighing completion can be output by setting f24 and f25. 
6  The start signal can be accepted after weighing completion even if the weight is 
not within the zero band. 
7  Over/Under output is set by f23  3x. 
 
Start
Start
Start
Start    
 
  Tare, when the Start is input automatically if f23 11. 
 
  The READY mark turns off when the Start is input. 
Weighing Completion
Weighing Completion
Weighing Completion
Weighing Completion    
 
  The weighing completion condition is set by f23  2x. 
 
      f23  20 : Either the STOP key is pressed or the Batch stop input is on. 
 
      f23  21 : Stable is detected after reaching Final. 
 
  Before reaching Final, the 
STOP
 key or Batch stop input forces weighing 
completion even if f23 21. 
 
10.2. Setpoint Comparison 
Final
Weighing value
Calibrated Zero
Tare 
Tared Zero
Zero band
Free fall
Preset target weight
Time
Weighing 
Relay HI,   1, -Net 
]
 - (Final - Free fall)
Relay OK*,   2,  Gross 
]
 Full 
Relay LO,   3,  Gross 
¢ Zero band 
ON
ON 
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
ON