Availability
Before installing the machine, consider the availability 
and proximity of the required power supply circuit. If an 
existing circuit does not meet the requirements for this 
machine, a new circuit must be installed. To minimize 
the risk of electrocution, fire, or equipment damage, 
installation work and electrical wiring must be done by 
a qualified electrician in accordance with all applicable 
codes and standards.
Full-Load Current Rating
The full-load current rating is the amperage a machine 
draws at 100% of the rated output power. On machines 
with multiple motors, this is the amperage drawn by the 
largest motor or sum of all motors and electrical devices 
that might operate at one time during normal operations.
Full-Load Current Rating at 110V ................ 16 Amps
Full-Load Current Rating at 220V ..................8 Amps
The full-load current is not the maximum amount of amps 
that the machine will draw. If the machine is overloaded, 
it will draw additional amps beyond the full-load rating.
If the machine is overloaded for a sufficient length of 
time, damage, overheating, or fire may result—especially 
if connected to an undersized circuit. To reduce the 
risk of these hazards, avoid overlovading the machine 
during operation and make sure it is connected to a 
power supply circuit that meets the requirements in the 
following section.
Electrocution,  fire,  or  equipment 
damage  may  occur  if  machine  is  not 
correctly  grounded  and  connected  to 
the power supply.
For your own safety and protection of 
property, consult a qualified electrician 
if you are unsure about wiring practices 
or electrical codes in your area.
ELECTRICAL