Woodstock M1001 User Manual

Page of 44
-11-
M1001 6" x 26" Vertical Mill
EL
EC
TR
IC
A
L
Note: The circuit requirements listed in this 
manual apply to a dedicated circuit—where 
only one machine will be running at a 
time. If this machine will be connected to 
a shared circuit where multiple machines 
will be running at the same time, consult 
a qualified electrician to ensure that the 
circuit is properly sized for safe operation.
Circuit Information
A power supply circuit includes all electrical equipment 
between the breaker box or fuse panel in the building 
and the machine. The power supply circuit used for 
this machine must be sized to safely handle the full-
load current drawn from the machine for an extended 
period of time. (If this machine is connected to a circuit 
protected by fuses, use a time delay fuse marked D.)
Circuit Requirements for 110V
This machine is prewired to operate on a 110V power 
supply circuit that has a verified ground and meets the 
following requirements:
Nominal Voltage ................................... 110V/120V
Cycle ........................................................60 Hz
Phase .............................................. Single-Phase
Minimum Circuit Size ............................... 20 Amps
Plug/Receptacle ................................... NEMA 5-15
Circuit Requirements for 220V
Nominal Voltage ................................... 220V/240V
Cycle ........................................................60 Hz
Phase .............................................. Single-Phase
Minimum Circuit Size ............................... 15 Amps
Plug/Receptacle ................................... NEMA 6-15
This machine can be converted to operate on a 220V 
power supply (refer to 
Voltage Conversion later in this 
section). The intended 220V circuit must have a verified 
ground and meet the following requirements: