SPX Cooling Technologies 17700-2K User Manual

Page of 32
7
34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit
Operating Guidelines
USING THE SELECTION MENU
1. Press the 
MENU
 button. The top line of the display reads SETUP MENU.
2. Use the 
UP
 and
 DOWN
 arrow keys to scroll through the menu choices
displayed on the second line. The menu choices are:
1. SELECT LANGUAGE
7. VACUUM OIL TIME
2. SELECT UNITS (ENGLISH/METRIC)
8. CHANGE VACUUM PUMP OIL
3. TANK REFILL
9. SELECT PROMPTS
4. RECYCLE ONLY
10. CHANGE DEFAULTS 
 (password protected)
5. FILTER CAPACITY
11. VERSION X.XX
6. CHANGE FILTER
3. Press 
START
 to make a choice from the menu. Press 
STOP
 to pause any
process, and 
STOP
 a second time to exit any process.
CHANGE FILTER
The filter-drier removes acid, particulates, and water from the refrigerant. Change
the filter-drier after 150 pounds (68 kg) of refrigerant has been filtered. See the
REPLACING THE FILTER DRIER section on the following page, as well as the
Maintenance Section, for instructions.
RECYCLE
Manual recycling may be necessary if excessive air and/or moisture is recovered
from the A/C system.
1. Press the 
MENU
 key. Use the arrow keys to select RECYCLE ONLY, and
press 
START
 to begin.
2. Press the 
START
 button to start recycling. To pause recycling, press the
STOP
 key. To terminate recycling, press the 
STOP
 key again, or press
START
 to resume.
TANK REFILL
1. Press the 
MENU
 key. Use the arrow keys to select TANK REFILL, and press
START
 to begin.
2.  Connect the fill hose to the source tank.
3. Open the tank valve. Invert the tank, install it on the back of the unit, and
secure the tank strap.