3.2.1 Naming Functions 
The matrix unit can be named.  Its name can be up to 10 characters long. 
To assign or retrieve a unit name: 
Command:
 NU<cr>     stands for Name Unit  
Response:  
xxxxxxxxxx (current name) 
Rename unit: ___________ 
No change<cr>    
If you hit <cr> or wait 5 seconds (command times out) the unit will respond with: 
Cancelled<cr> 
Otherwise you have 5 seconds to change the name by entering up to 10 ASCII 
characters followed by <cr>.  If you just send a <cr> then the stored name will not 
be changed.  If you enter more than 10 characters, then the 1
st
 10 characters will 
be saved as the name and the rest discarded. 
 
3.2.2 Routing Functions  
Video routing commands are specified from the point of view of the output. The 
wildcard character ‘*’ is acceptable for output (but not input). 
In addition, these commands can be used to monitor or query the status of system 
ties. Omitting the input channel will result in a response of the current routing for 
that output. In entering channel numbers leading zeros are acceptable hence you 
can specify channel 7 as 07 or just 7. 
 
3.2.2.1 To make a video tie: 
Command:
 CVn,m<cr>     stands for Connect Video n = output, m= input (unit 
accepts leading zeros and spaces are ignored)    
Response:  
CVn,m<cr> 
If you enter CVn<cr> then you will get the response as above for the n output  
3.2.2.2 To make an audio tie: 
Command:
 CAn,m<cr>     stands for Connect Audio n = output, m= input (unit 
accepts leading zeros and spaces are ignored)    
Response:  
CAn,m<cr> 
 
3.2.2.3 To make a synchronized audio/video tie: 
Command:
 COn,m<cr>     stands for Connect Output n = output, m= input (unit 
accepts leading zeros and spaces are ignored)