Black Box AC1120A User Manual

Page of 36
 
 
 
8x8 and 16x16 VGA / HDTV Matrix Switch with  Audio, RS232 & IP Control
19
 
3.2.6 To Read Audio Volume Units (VU) of output #1  
This command returns the height of hypothetical bar LED indicator having a 
height of 16 segments. It will return a number from 0 to 16 with 10 being 0 db 
level. So if the output #1 is at 0 dB (900 mv p-p sinewave) it returns 10. See 
figure 11 for 16x16 row. This value is 0-16 regardless of the type of matrix. 
Command:
 RB<cr>     stands for Read Bar 
Response:  
0 ~ 16<cr>
 
3.2.7 To Read Temperature inside the Matrix  
Command:
 RT<cr>     stands for Read Temperature    
Response:   
Temperature in degrees C = 32.500000<cr> 
Temperature in degrees F = 90.500000<cr> 
 
3.2.8 To Read the Firmware Version  
Command:
 RI<cr>     stands for Read Identity   
Response:
   
Unit's name: 
← User defined name of the unit 
Version 2.3 
← Firmware Version 
Build # 7 
← Build number (for mfg purposes only) 
BBox-I-A-8-8 
← Characteristics of the unit 
 
3.2.9 To Read Supply Voltages  
The supply voltages consist of clock battery voltage, 5V supply, and 12V supply. 
Command:
 RV<cr>     stands for Read Voltages   
Response:   
RTC Battery Voltage = 2.9876704 
+5V Supply = 4.9473252 
+12V Supply = 12.4646893 
 
3.2.10 Real Time Clock Functions  
3.2.10.1 To set date & time: 
Command:
 DS<cr>     stands for Date Set    
Response:   
Friday 04/18/08 12:27:15pm  
 
Enter the year (00-99):    
Hit Enter if you want to keep previous value; hit Esc to exit
 
Enter the month (01-12):     
Enter the date (01-31):      
Enter the day of the week (1=Sun – 7=Sat):    
 
Enter the hour (1-12):      
Enter the minute (00-59):