Installation
21
M414905
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To Reverse the Loading Door
A, H, S and U models after serial number 
0308001307
The tumbler is delivered with a right hinged door, but 
the door can be changed to a left hinged position.
1. Disconnect power supply to tumbler.
2. Unlock and remove control panel. Remove two 
control assembly mounting screws from right 
side. Swing open control to access upper flange 
right guide lug assembly. Refer to Figure 6.
3. Remove lint panel.
IMPORTANT: Support door and hinge assembly 
securely to prevent it from dropping once side 
screws are removed from door hinge lug.
Figure 6 
WARNING
To reduce the risk of electric shock, fire, 
explosion, serious injury or death:
• Disconnect electric power to the 
tumbler before servicing.
• Close gas shut-off valve to gas tumbler 
before servicing.
• Close steam valve to steam tumbler 
before servicing.
• Never start the tumbler with any guards/
panels removed.
• Whenever ground wires are removed 
during servicing, these ground wires 
must be reconnected to ensure that the 
tumbler is properly grounded.
W002
TMB1994N
1
Control Assembly Mounting Screw
2
Control Assembly
3
Guide Lug Assembly
4
Side Screw
5
Screw
6
Lint Panel
7
Front Panel
8
Control Panel
TMB1994N
1
2
3
4
5
6
4
7
5
8