Sterling 882.00290.00 User Manual

Page of 53
Entering Operating Parameters to Select Modes 
To enter the display:   
1. 
Press the 
 Mode Display key to view the Run/Stop & Alarm 1 Modes. 
2. 
Press 
 and 
 to set the higher or lower the values of the parameter or turn that 
function On or Off. 
The 
SV readout
 displays the different values for the parameter within a mode. 
3. 
To switch modes within a level, press and hold the 
 Level Display key for one (1) 
second. 
The 
PV
 readout will display the different parameters within each mode. 
4. 
Use short presses on the 
 Mode Display key to display each parameter within a mode. 
The 
SV
 readout displays the different values for the parameter within a mode. 
5. 
Press 
 and 
 to set the higher or lower the values of a parameter or turn that 
function On or Off. 
6. 
Press 
 Level Key once to return to the Process Temperature Setting. 
Figure 6:  Settings for Process Temperature Controller (E5CN), Part No. A0567917 
 
Mode 
Parameter 
Setting range 
Default 
Manuf. setting
Run/Stop Run/Stop Run 
Operation 
Alarm value 1 
-1999 to 9999 
35 
 
Mode 
Parameter 
Setting range 
Default 
Manuf. setting
AT execute/cancel 
ON, OFF 
OFF 
Temperature input shift 
-199.9 to 999.9 
0.0 
Proportional Band 
0.1 to 999.9 
8.0 
Integral Time 
0 to 3999 
233 
Adjustment 
Derivative Time 
0 to 3999 
40 
 
 
 
 
 
 
 
 
Dehumidifying Dryers 
Chapter 4: Operation 
24 of 53