TE Connectivity LAN Cat.6 UTP 0-1711091-2 User Manual

Product codes
0-1711091-2
Page of 7
 
 
 
108-93017
 
 
Rev D 
2 of 7
 
 
INGF-070 
 
 
H.  IEC 60512-4-1: 
Electromechanical Components for Electronic Equipment; Basic Testing  
 
 
 
 
 
      procedures and measuring methods. Test 4a: Voltage Proof. 
 
    
3. 
REQUIREMENTS 
 
3.1 
Design and Construction 
 
Product shall be of design, construction and physical dimensions specified on applicable customer drawing. 
 
3.2 
Standard length 
 
Applicable standard lengths: from 0.5meter to 20meter (both included). 
For other lengths, put in contact with your sales representative. 
 
3.3 
Materials 
 
Materials shall be in accordance to Tyco Electronics requirements about environmental-related substances as 
per Tyco Electronics specification 230-702.  
The  material  of  the  cable  jacket  is  identified  on  the  customer  drawing  and  shall  comply  with  the  standards 
mentioned in Product Specification 108-93018 Copper LAN cable
 
3.4 
Ratings 
 
Operating Temperature: 
-20 to 60ºC 
 
3.5 
Packaging 
 
Each assembly shall be supplied in a clear bag. 
 
3.6 
Bending radius 
 
The  minimum  bending  radius  is  8x  outside  diameter  during  installation  and  4x  the  outside  diameter  after 
installation. 
 
3.7 
Performance requirements and test procedures 
 
Product is designed to meet electrical, mechanical and environmental performance requirements specified in 
Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions.