TE Connectivity LAN Cat.6 UTP 0-1711091-2 User Manual

Product codes
0-1711091-2
Page of 7
 
 
 
108-93017
 
 
Rev D 
3 of 7
 
 
INGF-070 
 
 
Test Description 
Requirement 
Test Procedure 
                                                               VISUAL
  
Examination 
of 
product. 
Meets requirements of product drawing. 
Visual inspection criteria as defined in IEC 
61935-2, Paragraph 5.1. 
 
                                                           ELECTRICAL
 
Wire map 
Continuity and short circuit  
Wire map configuration as per TIA 568B 
Any device which ensures quality  
 
AMPTRAC 
connection (9
th
 wire) 
(only  applicable  for 
AMPTRAC versions) 
Continuity and short circuit (between pogo 
pin and plug shield) 
Any device which ensures quality. 
(See figure 2 as information) 
Voltage proof 
(only  applicable  for 
AMPTRAC versions) 
 
1  minute  hold  with  no  breakdown  or 
flashover 
IEC 60512-4-1 
1500  volts  AC  peak  voltage  to  be  applied 
between pogo pin and plug shield. 
Maximum leakage current 5 mA 
                                                        
TRANSMISSION
 
(See Figure 3 for transmission tests in Channel set up)
 
Return Loss 
Class E Channel Return Loss 
requirements according to ISO/IEC 11801 
2
nd
 Edition  
IEC 61935-1, Paragraph 4.11 
 
Insertion Loss 
Class E Channel Insertion Loss 
requirements according to ISO/IEC 11801 
2
nd
 Edition  
IEC 61935-1, Paragraph 4.5 
 
NEXT Loss 
Class E Channel NEXT requirements 
according to ISO/IEC 11801 2
nd
 Edition 
IEC 61935-1, Paragraph 4.7 
PS NEXT Loss 
Class E Channel PS NEXT requirements 
according to ISO/IEC 11801 2
nd
 Edition 
(PS NEXT is computed  from NEXT Loss 
values) 
ACR-N 
Class E Channel ACR-N requirements 
according to ISO/IEC 11801 2
nd
 Edition 
IEC 61935-1, Paragraph 4.8 
PS ACR-N 
Class E Channel PS ACR-N requirements 
according to ISO/IEC 11801 2
nd
 Edition 
(PS ACR-N is computed  from ACR-N 
values) 
FEXT Loss 
(There are no requirements for FEXT 
Loss) 
IEC 61935-1, Paragraph 4.9 
ACR-F 
Class E Channel ACR-F requirements 
according to ISO/IEC 11801 2
nd
 Edition 
IEC 61935-1, Paragraph 4.10 
PS ACR-F  
Class E Channel PS ACR-F requirements 
according to ISO/IEC 11801 2
nd
 Edition 
(PS ACR-F is computed  from ACR-F 
values) 
Propagation delay 
Class E Channel Prop Delay 
requirements according to ISO/IEC 11801 
2
nd
 Edition 
IEC 61935-1, Paragraph 4.6 
Delay Skew 
Class E Channel Delay Skew 
requirements according to ISO/IEC 11801 
2
nd
 Edition  
IEC 61935-1, Paragraph 4.6 
                                                                     
MECHANICAL
 
Crimping Height 
Relevant IEC 60603-7-X standard 
Indicator  with  needle-point  probes  or 
equivalent. 
It  shall  be  measured  at  the  front  of  the 
contact. 
Tensile Strength 
 
Force  applied:  50  N  according  to  the 
standard. Duration: 5 seconds 
IEC 61935-2, Paragraph 6.2. 
(See figure 4 as information) 
Torsion Force 
(specified  by  Tyco 
Electronics) 
Force applied: 10 N x cm  
Duration: 5 seconds 
Maximum Rotation angle 45º 
(See figure 5 as information)
 
NOTE 
See Test Sequence in paragraph 4.2 Figure 6 
Figure 1Requirements and test procedures for Cat 6 unshielded patch cords