Installation Clearances
The location must be large enough to allow the dryer door to open 
fully. 
Dryer Dimensions
*Most installations require a minimum 5" (127 mm) clearance 
behind the dryer for the exhaust vent with elbow. See “Venting 
Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this 
dryer. This dryer has been tested for spacing of 0" (0 mm) 
clearance on the sides and rear. Recommended spacing should 
be considered for the following reasons:
Additional spacing should be considered for ease of 
installation and servicing.
Additional clearances might be required for wall, door, 
and floor moldings.
Additional spacing should be considered on all sides of the 
dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
Companion appliance spacing should also be considered. 
*Required spacing
Mobile Home - Additional Installation Requirements
This dryer is suitable for mobile home installations. 
The installation must conform to the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction and 
Safety, Title 24, HUD Part 280) or the Canadian Manufactured 
Home Standard, CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for 
purchase from your dealer.
Special provisions must be made in mobile homes to 
introduce outside air into the dryer. The opening (such as a 
nearby window) should be at least twice as large as the dryer 
exhaust opening.
Electrical Requirements - U.S.A.
It is your responsibility
To contact a qualified electrical installer.
To be sure that the electrical connection is adequate and in 
conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition and all local codes and ordinances. 
The National Electrical Code requires a 4-wire supply 
connection for homes built after 1996, dryer circuits involved 
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from: 
National Fire Protection Association, One Batterymarch Park, 
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 volt, 
60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt 
electrical supply, if specified on the serial/rating plate) on a 
separate 30-amp circuit, fused on both sides of the line. A 
time-delay fuse or circuit breaker is recommended. Connect 
to an individual branch circuit. Do not have a fuse in the 
neutral or grounding circuit. 
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
A. Small opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
43 "
(1102 mm)
*26"
(660 mm)
29"
(737 mm)
A
15¼"
(387 mm) 43 "
(1102 mm)
*27¾"
(705 mm)
29"
(737 mm)
B
22¾"
(578 mm)
43 "
(1102 mm)
13¾"
(349 mm)
*27¾"
(705 mm)
29"
(737 mm)
D
43 "
(1102 mm)
*27¾"
(705 mm)
29"
(737 mm)
C
22¾"
(578 mm)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
A
B
C
    18"*
(457 mm)
  1"
(25 mm)
       29"
(737 mm)
        1"
   (25 mm)
        1"*
    (25 mm)
14" max.*
(356 mm)
   27¾"
(705 mm)
   5"*
 (127 mm)
  48 in.  
(310 cm  )
2
*
2
  24 in.
(155 cm  )
*
2
       3"*
(76 mm)
       3"*
(76 mm)
3
8
3
8
3
8
3
8