Amana W10216186A User Manual

Page of 28
10
2. Remove neutral ground wire from external ground conductor 
screw. Connect neutral ground wire and the neutral wire 
(white or center wire) of power supply cord under center, 
silver-colored terminal block screw. Tighten screw.
A
C
B
D
E
A. External ground conductor screw - Dotted line shows 
position of NEUTRAL ground wire before being moved 
 
to center silver-colored terminal block screw.
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire) 
E. ¾" (19 mm) UL listed strain relief
3. Connect ground wire (green or bare) of power supply cord 
 
to external ground conductor screw. Tighten screw.
B
A
C
D
E
F
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cord
C.
¾
" (19 mm) UL listed strain relief
D. Center silver-colored terminal block screw
E. Neutral ground wire
F. Neutral wire (white or center wire)
4. Connect the other wires to outer terminal block screws. 
Tighten screws. 
5. Tighten strain relief screws.
6. Insert tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw.
7. You have completed your electrical connection. Now go to 
“Venting Requirements.”
4-wire connection: Direct wire  
IMPORTANT: A 4-wire connection is required for mobile homes 
and where local codes do not permit the use of 3-wire 
connections.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer 
can be moved if needed. 
Strip 5" (127 mm) of outer covering from end of cable, leaving 
bare ground wire at 5" (127 mm). Cut 1½" (38 mm) from 
3 remaining wires. Strip insulation back 1" (25 mm). Shape ends 
of wires into a hook shape.
     1"
(25 mm)
       5"
(127 mm)
When connecting to the terminal block, place the hooked end of 
the wire under the screw of the terminal block (hook facing right), 
squeeze hooked end together and tighten screw, as shown.  
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor 
screw. Connect neutral ground wire and place the hooked 
end (hook facing right) of the neutral wire (white or center 
wire) of direct wire cable under the center screw of the 
terminal block. Squeeze hooked ends together. Tighten 
screw.
A
C
B
D
E
A. External ground conductor screw - Dotted line shows 
position of NEUTRAL ground wire before being moved 
 
to center silver-colored terminal block screw.
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire) 
E. ¾" (19 mm) UL listed strain relief