Amana W10216186A User Manual

Page of 28
12
3-wire connection: Direct wire
Use where local codes permit connecting cabinet-ground 
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer 
can be moved if needed. 
Strip 3½" (89 mm) of outer covering from end of cable. Strip 
insulation back 1" (25 mm). If using 3-wire cable with ground 
wire, cut bare wire even with outer covering. Shape ends of wires 
into a hook shape.
    1"
(25 mm)
    3½"
(89 mm)
When connecting to the terminal block, place the hooked end of 
the wire under the screw of the terminal block (hook facing right), 
squeeze hooked end together and tighten screw, as shown.
1. Loosen or remove center silver-colored terminal block screw.
2. Place the hooked end of the neutral wire (white or center wire) 
of direct wire cable under the center screw of terminal block 
(hook facing right). Squeeze hooked end together. Tighten 
screw. 
A
C
D
B
E
A. External ground conductor screw
B. Neutral ground wire
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E. ¾" (19 mm) UL listed strain relief
3. Place the hooked ends of the other direct wire cable wires 
under the outer terminal block screws (hooks facing right). 
Squeeze hooked ends together. Tighten screws.
4. Tighten strain relief screw.
5. Insert tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw.
6. You have completed your electrical connection. Now go to 
“Venting Requirements.”
Optional 3-wire connection
Use for direct wire or power supply cord where local codes 
do not permit connecting cabinet-ground conductor to 
neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor 
screw. Connect neutral ground wire and the neutral wire 
(white or center wire) of power supply cord/cable under 
center, silver-colored terminal block screw. Tighten screw.
A. External ground conductor screw
B. Center silver-colored terminal block screw
C. Neutral ground wire
D. Neutral wire (white or center wire)
E. ¾" (19 mm) UL listed strain relief
F. Grounding path determined by a qualified electrician
A
B
C
D
F
E
3. Connect the other wires to outer terminal block screws. 
Tighten screws.
4. Tighten strain relief screws.
5. Connect a separate copper ground wire from the external 
ground conductor screw to an adequate ground.
6. Insert tab of terminal block cover into slot of dryer rear panel. 
Secure cover with hold-down screw.