Frigidaire 137153700B User Manual

Page of 36
Gas connection
Remove the shipping cap from gas pipe at the rear of the 
1. 
dryer.
Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved 
2. 
pipe from gas supply line to the 3/8 inch (0.96 cm) pipe 
located on the back of the dryer. Use a 1/2 inch to 3/8 
inch (1.27 cm to 0.96 cm) reducer for the connection. 
Apply an approved thread sealer that is resistant to the 
corrosive action of liquefi ed gases on all pipe connections.
Open the shutoff valve in the gas supply line to allow gas 
3. 
to fl ow through the pipe. Wait a few minutes for gas to 
move through the gas line.
All connections must be wrench-tightened
Flare
Union
Flare
Union
GAS FLOW
Manual
Shutoff
Valve
Closed
Open
Flexible
Connector
Inlet Pipe on
Back of Dryer
e
l
p
p
i
N
Shutoff Valve -
Open position
to dr
yer
from gas supply
Check for gas system leaks with a manometer. If a 
4. 
manometer is not available, test all connections by 
brushing on a soapy water solution.
10
 - EXPLOSION HAZARD - NEVER test for gas 
leaks with an open fl ame.
 The supply line must be equipped with an ap-
proved manual shutoff valve. This valve should be located in 
the same room as the dryer and should be in a location that 
allows ease of opening and closing. Do not block access to 
the gas shutoff valve.
 DO NOT connect the dryer to L.P. gas service 
without converting the gas valve. An L.P. conversion kit must 
be installed by a qualifi ed gas technician.
Electrical connection (non-Canada) 3-wire cord
Turn off power supply to outlet. 
1. 
Remove the screw securing the terminal block access cover in the 
2. 
upper corner on the back of the dryer.
Install a UL-approved strain relief according to the power cord/
3. 
strain relief manufacturer’s instructions in the power cord entry 
hole below the access panel. At this time, the strain relief should 
be loosely in place.
Thread an UNPLUGGED, UL-approved, 30 amp. power cord, 
4. 
NEMA 10-30 type SRDT, through the strain relief.
Attach the power cord neutral (center wire) conductor to the 
5. 
SILVER colored center terminal on the terminal block. Tighten the 
screw securely.
Attach the remaining two power cord outer conductors to the 
6. 
outer, BRASS colored terminals on the terminal block. Tighten 
both screws securely.
3-wire
receptacle
(NEMA type
10-30R)
Neutral 
terminal
Neutral
Neutral
(center wire)
(center wire)
30 AMP
30 AMP
NEMA 10-30
NEMA 10-30
Follow manufacturer’s guidelines for fi rmly securing the strain 
7. 
relief and power cord. 
Reinstall the terminal block cover.
8. 
 - ELECTRICAL SHOCK HAZARD - Failure 
to disconnect power source before servicing could result in 
personal injury or even death.
 - ELECTRICAL SHOCK HAZARD - Do not 
make a sharp bend or crimp wiring/conductor at connections.
 If moving dryer from a 4-wire system 
and installing it in a 3-wire system, move the internal 
ground from the center terminal back to the GREEN 
screw next to the terminal block.
DO NOT remove 
internal ground in a 
3-wire system!