The following are specifi c requirements for proper and safe 
electrical installation of your dryer. Failure to follow these 
instructions can create electrical shock and/or a fi re hazard.
Electrical installation
Front Console Dimensions
Rear Console Dimensions
 - ELECTRICAL SHOCK HAZARD -
This appliance MUST be properly grounded. Electrical 
• 
shock can result if the dryer is not properly grounded. Fol-
low the instructions in this manual for proper grounding.
Do not use an extension cord with this dryer. Some ex-
• 
tension cords are not designed to withstand the amounts 
of electrical current this dryer utilizes and can melt, creat-
ing electrical shock and/or fi re hazard. Locate the dryer 
within reach of the receptacle for the length power cord 
to be purchased, allowing some slack in the cord. Refer 
to the pre-installation requirements in this manual for the 
proper power cord to be purchased.
 - ELECTRICAL SHOCK HAZARD -
A U.L.-approved strain relief must be installed onto pow-
• 
er cord. If the strain relief is not attached, the cord can be 
pulled out of the dryer and can be cut by any movement 
of the cord, resulting in electrical shock.
Do not use an aluminum wired receptacle with a copper 
• 
wired power cord and plug (or vice versa). A chemical 
reaction occurs between copper and aluminum and can 
cause electrical shorts. The proper wiring and receptacle 
is a copper wired power cord with a copper wired recep-
tacle.
 Dryers operating on 208 volt power supply will have 
longer drying times than dryers operating on 240 volt power 
supply.
2 9/16”
(6.5 cm)
4 3/8”
(11 cm)
4 3/8”
(11 cm)
3 3/4”
(9.5 cm)
3 3/4”
(9.5 cm)
27” (68.6 cm)
27” (68.6 cm)
2 9/16”
(6.5 cm)
1”
(2.5 cm)
1”
(2.5 cm)
13 1/2”
(34.4 cm)
13 1/2”
(34.4 cm)
3 3/4”
(9.5 cm)
3 3/4”
(9.5 cm)
36”
(91.5 cm)
36”
(91.5 cm)
43 5/8”
(111 cm)
34 5/8”
(87.9 cm)
electrical supply on rear of unit,
power cord length on gas unit
approximately 59” (150 cm)
to center of 
rear vent
to center of 
rear vent
gas supply pipe on 
rear of gas unit
47 1/2” (120.7 cm)
to clear open door
47 1/2” (120.7 cm)
to clear open door
optional vent
knockout
optional vent
knockout
gas supply pipe on 
rear of gas unit
center line 
height for 
rear vent
center line 
height for 
rear vent
under-counter 
installation height
electrical supply on rear of unit,
power cord length on gas unit
approximately 59” (150 cm)