Crosley W10151585B User Manual

Page of 16
4
Location Requirements
You will need
A location that allows for proper exhaust installation. See 
“Venting Requirements.”
A 120-volt, 60-Hz., AC-only, 15- or 20-amp circuit.
A grounded electrical outlet located within 2 ft (610 mm) of either 
side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the dryer weight (dryer and load) of 
 
115 lbs (52 kg). The combined weight of a companion appliance 
should also be considered.
A level floor with a maximum slope of 1" (25 mm) under entire 
dryer.
Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will be 
exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
Installation Clearances
The location must be large enough to allow the dryer door to open 
fully.
23
7
8
(606 mm)
"
20
3
4
(527 mm)
"
31"
(787 mm)
*
Dryer Dimensions
†Height with caster is 32½" (826 mm)
*Most installations require a minimum 5" (127 mm) clearance 
behind the dryer for the exhaust vent with elbows. See “Venting 
Requirements.”
Minimum spacing for recessed area and closet installation
The following dimensions shown are for the minimum spacing 
allowed when the dryer is to be operated with, or without, the Stack 
Stand Kit. To purchase a Stack Stand Kit, see “Assistance or 
Service.” 
Additional spacing should be considered for ease of installation 
and servicing.
Additional clearances might be required for wall, door, and floor 
moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer is 
recommended to reduce noise transfer.
For closet installation with a door, minimum ventilation openings 
in the top and bottom of the door are required. Louvered doors 
with equivalent ventilation openings are acceptable.
Companion appliance spacing should also be considered.
Recessed or closet installation - Dryer only
A. Side view - closet or confined area
B. Recessed area
A
B
     3"*
(76  mm)
      14"*
(356  mm)
18"* (457  mm)
 1"
(25 mm)
      1"
(25 mm)
Recessed or closet installation - Stacked
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
DRYER
WASHER
      (76 mm)
 3"*
  (305 mm)
  12"*
 (305 mm)
  12"*
1"
(25 mm)
     1"
(25 mm)
A
B
C
1"*
(25 mm)
     3"*
(76 mm)
48 in. *
2      
(309.7 cm )
2
24 in. *
2
(154.8 cm )
2
     3"*
(76 mm)
Mobile Home - Additional Location Requirements
This dryer is suitable for mobile home installations. The installation 
must conform to the Manufactured Home Construction and Safety 
Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for 
Mobile Home Construction and Safety, Title 245, HUD Part 280) or 
Standard CAN/CSA-Z240 MH.