Mobile home installations require:
Metal exhaust system hardware, which is available for purchase 
from your dealer.
Special provisions must be made in mobile homes to introduce 
outside air into the dryer. The opening (such as a nearby 
window) should be at least twice as large as the dryer exhaust 
opening.
Electrical Requirements
A 120-volt, 60-Hz., AC-only, 15- or 20-amp fused electrical 
supply is required.
A time-delay fuse or circuit breaker is recommended. Be sure 
fuse or circuit breaker matches the rating of your line.
Use a separate circuit serving only your dryer.
Do not use an extension cord.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■  
For a grounded, cord-connected dryer: 
This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment- 
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
WARNING: 
Improper connection of the equipment- 
grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with 
the dryer: if it will not fit the outlet, have a proper outlet 
installed by a qualified electrician.
Venting Requirements
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, attic, crawlspace, or a concealed space 
 
of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure 
exhaust hood is not plugged with lint. 
Replace any plastic or metal foil vent with rigid or flexible heavy 
metal vent.
Review Vent system chart. Modify existing vent system if 
necessary to achieve the best drying performance. Only rigid 
 
or flexible metal vent shall be used for exhausting.
If this is a new vent system 
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (102 mm) heavy metal exhaust vent and clamps must be 
used. 
4" (102 mm) heavy metal exhaust vent
Rigid metal vent
For best drying performance, rigid metal vents are 
recommended.
Rigid metal vent is recommended to avoid crushing and kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for 
cleaning.
Flexible metal vent must be fully extended and supported when 
the dryer is in its final location. 
Remove excess flexible metal vent to avoid sagging and kinking 
that may result in reduced airflow and poor performance.