Sony HVL-MT24AM User Manual

Page of 295
HVL-MT24AM_GB  2-889-493-01 (1)
A
dditional Inf
orma
tion
Manual flash metering
Flash-subject
distance
A
pe
rtu
re
Flash power line
Flash power line
1/1
1/2 (1/1)
1/4 (1/2)
1/8 (1/4)
1/16 (1/8)
1/32 (1/16)
1/64 (1/32)
(1/64)
1/1
1/2 (1/1)
1/4 (1/2)
1/8 (1/4)
1/16 (1/8)
1/32 (1/16)
1/64 (1/32)
(1/64)
The following explains how to obtain the aperture using the two twin flash units 
with a power level of 1/1 at 1.5 m flash-to-subject distance and at ISO 100.
1  Draw a vertical line upwards from the flash-to-subject distance until it reaches 
the flash power line that corresponds to the set power level ().
2  Draw a horizontal line leftwards from  until it reaches the vertical ISO line 
corresponding to the camera used ().
3  Draw a diagonal line from  upwards and leftwards. The result indicates the 
aperture that will provide the proper exposure ().
In this case, the proper exposure can be obtained by setting the camera’s aperture 
to f/16.
  The figures in parenthesis are employed when only one twin flash unit is used.