Kodak GE680 User Manual

Page of 21
GE680 User Manual 
 
70-0026A-A
 
Prosilica Inc. 
 
 
Sync Out 2 and Sync Out 3 
These signals only function as outputs and can be configured as follows: 
 
Exposing 
Corresponds to when camera is 
integrating light. 
Trigger Ready 
Indicates when the camera will accept a 
trigger signal. 
Trigger Input 
A relay of the trigger input signal used 
to “daisy chain” the trigger signal for 
multiple cameras. 
Readout 
Valid when camera is reading out data. 
Strobe 
Programmable pulse based on one of the 
above events. 
Imaging 
Valid when camera is exposing or 
reading out. 
GPO 
User programmable binary output. 
 
Any of the above signals can be set for active high or active low. 
RS-232 RXD and RS-232 TXD 
These signals are RS-232 compatible.  These signals allow communication from the host system 
via the Ethernet port to a peripheral device connected to the camera. 
ISOLATED GROUND 
These signals are internally connected to isolated ground.  At least one of these signals must be 
connected  to  the  users  external  circuit  ground.    However,  it  is  good  practice  to  provide  a 
dedicated ground return for each signal used.  For example, a good cable design would connect 
the  required  signal  on  one  conductor  of  a  twisted  pair  and  the  isolated  ground  on  the  second 
conductor of the same twisted pair. 
DNC 
These signals are reserved for future use and should be left disconnected. 
Item 3: Mini-SMB Trigger Input  
The  Mini-SMB  port  on  the  camera  uses  an  Amphenol  903-406J-51R  connector.    A  suitable 
mating cable connector is Amp 413985-3 which can be used with RG174 coaxial cable.  Contact 
Prosilica to purchase cabling. 
The Mini-SMB Trigger Input is internally connected to the Trigger Input (Pin 1) of the General 
Purpose I/O Port (Item 2 above).  Therefore see this section for more detail.