Sony SNC-RZ30P User Manual

Page of 44
Ad
minis
tra
ting t
he Camer
a
Recording Images in Memory — Image memory setting Page
37
Alarm
Select the alarm to link the Image memory function.  If 
the selected alarm is detected, a still image is captured 
and recorded in the selected memory.
Sensor 1: External sensor connected to sensor input 1 of 
the camera I/O port 
Sensor 2: External sensor connected to sensor input 2 of 
the camera I/O port 
Sensor 3: External sensor connected to sensor input 3 of 
the camera I/O port 
Activity detection: The activity detection function built 
in the camera.
To set the activity detection function, click Activity 
detection
.  The Activity detection setting page 
appears (see page 40).
Available period
Select the period for which the alarm mode is available.
Always: The alarm mode is available any time.
Use scheduler: The alarm mode is available according 
to the schedule selected in the Schedule No. menu 
below.
Schedule No.
When Use scheduler is selected on the Available period 
menu, select the schedule you want the alarm mode 
being available.
Click to select the check box(es) 1 to 6.  You can select 
multiple schedules.
To check the contents of schedules, click Schedule 
check
.  (See “Setting the Schedule — Schedule setting 
Page” on page 40
.)
Alarm buffer configuration
Click Alarm buffer to display the Alarm buffer setting 
page.
For details, see “Setting the Alarm Buffer — Alarm 
buffer setting Page” on page 38
.
Note
If an alarm occurs during the Alarm buffer processing, 
that alarm is ignored.
Digest viewer
If you select On, an HTML file (.html) and a Java Script 
file (.js) are added each time the selected alarm is 
detected.
When you open the added HTML file using a general 
browser, the digest viewer runs and you can view the 
still pictures in the alarm buffer in sequence (quasi-
animation).
See “Operating the Digest Viewer” on page 30.
Periodical recording mode setting 
Section
Interval time
Type the interval at which you want to record an image 
periodically. You can set the hour (H), minutes (M) and 
seconds (S) between 1 second and 24 hours (one day).
Available period
Select the period for which the periodical recording 
mode is available.
Always: The periodical recording mode is available any 
time.
Use scheduler: The periodical recording mode is 
available according to the schedule selected in the 
Schedule No. menu below.
Schedule No.
When Use scheduler is selected on the Available period 
menu, select the schedule you want the periodical 
recording mode being available.
Click to select the check box(es) 1 to 6.  You can select 
multiple schedules.
To check the contents of schedules, click Schedule 
check
.  (See “Setting the Schedule — Schedule setting 
Page” on page 40.
)
Digest viewer
If you select On, an HTML file (.html) and a Java Script 
file (.js) are added every 100 files.
When you open the added HTML file using a general 
browser, the digest viewer runs and you can view the 
still pictures in the alarm buffer in sequence (quasi-
animation).
See “Operating the Digest Viewer” on page 30.
Note
If the Suffix menu is set to None, you cannot select On
When you want to use the digest viewer, set the Suffix 
menu to Date/Time or Sequence number.
Back/OK