Setting the Alarm Buffer — Alarm buffer setting Page
38
Directory Structure of Image 
Memory 
The images are recorded in the memory with the 
following directory structure.
ATA memory card (A-slot): Slot A
ATA memory card (B-slot): Slot B
Built-in memory: Drive C
Each slot or drive has the following directory structure.
 represents a folder created automatically.  The 
Date folder has a 6-digit folder name consisting of the 
lower two digits of year (2 digits), month (2 digits) and 
date (2 digits) .  The Sensor 1, Sensor 2, Sensor 3 and 
Act Det (activity detection) folders correspond to alarm 
modes. The Timer folder corresponds to the periodical 
recording mode.  And, the Manual folder corresponds to 
the manual mode.
JPEG image files are stored in each folder.  If the digest 
viewer is allowed, an HTML file (.html) and a Java 
Script file (.js) are created automatically at the time of 
each alarm event.  For the periodical recording mode, an 
HTML file (.html) and a Java Script file (.js) are created 
automatically every 100 JPEG image files.
Setting the Alarm Buffer 
— Alarm buffer setting Page
When you click Alarm buffer on the Administrator 
menu, the Alarm buffer Setting page appears.
Use this page to set up for the alarm buffer used in the 
FTP client function (see page 28) and the Image 
memory function (see page 35).
Recording interval
Select the interval (in seconds) at which you want to 
record an image in the alarm buffer.
You can select from among the following intervals:
SNC-RZ30N:
1/301/151/101/51/212345678910 
(seconds)
SNC-RZ30P:
1/251/121/81/51/212345678910 
(seconds)
Pre-alarm images
Type the number of images to be recorded before 
detecting an alarm (Pre-alarm).
Post-alarm images
Type the number of images to be recorded after 
detecting an alarm (Post-alarm).
Maximum alarm images
Displays the maximum number of images that can be 
recorded in the alarm buffer with the current image size 
and image quality.
Note
The number of Maximum alarm images differs 
depending on the Image size and Image quality settings 
on the Camera setting page.
Check the Maximum alarm images setting and set so 
that the total number of Pre-alarm images and Post-
alarm images does not exceed the Maximum alarm 
images.
If you set both Pre-alarm images and Post-alarm images 
to 0, only one image is recorded at the moment when an 
alarm is detected.
OK/Cancel
Date
Alarm
Timer
Manual
Sensor 1
Sensor 2
Sensor 3
ActDet
xxxxxxx.jpg
aaaaaa.html
aaaaaa.js
yyyyyyy.jpg
bbbbbb.html
bbbbbb.js
zzzzzzz.jpg
cccccc.html
cccccc.js
ddddddd.jpg
eeeeeee.jpg
ffffffff.jpg
Drive root