Panasonic AW-PH400 User Manual

Page of 64
Indoor Pan/Tilt Head  AW-PH400
AW-PH400
19
Replacing the consumable parts
$
Replacing the battery
The battery has a service life of approximately 5 years.
The unit stores the preset positions, limiters and other data in its memory. This data is retained even when the power is turned
off, but if the internal battery has reached the end of its service life, the data will be lost when the power is turned off.
Replace a battery that has lost its charge with a new one. (Battery used: CR2032 manganese dioxide-lithium battery)
$
How to remove the battery
1
Remove the four screws, and remove the pedestal connector
panel.
2
Push the battery in the direction indicated by the arrow in the
figure, and slide it out.
3
With the battery slid out, raise it from underneath the part with the
arrow.
4
After disengaging the part with the arrow from the battery holder,
pull the battery out toward yourself.
$
How to install the battery
1
Make the “+” side of the new battery to the front side, and insert
its end into the battery holder from the direction of the arrow.
2
Push the battery into the holder while pushing the battery in the
direction of the arrow.
3
Attach the pedestal connector panel using the four screws.
$
Replacing the motor
Replace the motor when it ceases to operate properly.
For details on the motor replacement, consult your dealer.
$
Replacing the belt
Replace the belt when the preset stop accuracy has deteriorated.
For details on the belt replacement, consult your dealer.
$
Replacing the gear
Replace the gear when the preset stop accuracy has deteriorated.
For details on the gear replacement, consult your dealer.
The motor, gear and belt are consumables.
They need to be replaced at periodic intervals.
Replace the lithium
battery here.
Pedestal connector panel