Polycom 128 User Manual

Page of 140
Troubleshooting
126
ViewStation User’s Guide
Symptom
Cause
Solution
IMUX 512 (Inverse Multiplexer)
Cannot dial remote 
system in BONDING 
384K calls
Call progress circles only 
show blue or yellow.
Start by calling the far-site at 1x64 or 
2x64K.  This will verify if the primary 
number is correct. If these calls complete, try 
256K then 384K.
Dialing a remote site in 
calls above 128K does 
not work.
Call progress circles do not 
turn green, or remain blue 
after the first channel 
connects.
Go to the call status screen.  Highlight each 
of the circles for each of the channels dialed.  
The number dialed for each channel will be 
displayed as you highlight the 
corresponding circle. Make sure that the far-
site has entered the number for each of their 
ISDN lines correctly.  The numbers for Line 1 
- Line 4 should correspond with connections 
1 - 4 on the IMUX.
System will not start.
System restarts over and over 
again.
Defective cable between the IMUX and 
ViewStation. Check that the green lights on 
each ISDN card are on and that the green 
light on the top of the IMUX is on (red on 
older units).  The cable from the IMUX to the 
ViewStation is a straight RJ-45 x RJ-45 cable. 
Bad power supply.
Cannot select 112 or 128 
speeds for BONDING 
calls from the speed 
selection icon on the 
Video Phone.
Speeds do not show when 
selecting the speed icon.
Add line speeds by going to the IMUX 
Dialing Speeds screen.
LAN/Intranet
Cannot access 
ViewStation from your PC 
browser.
DHCP Client is ON and no 
DHCP server is available.
Contact your network administrator.
LAN cable is connected to the 
PC port.
Connect the LAN cable to the LAN port on 
the rear of the ViewStation.
Bad LAN cable.
Check the light on the back of the 
ViewStation. You should have a steady 
green light to indicate a connection to the 
LAN and a flashing orange light to indicate 
LAN traffic.
There is a firewall between 
your PC and your 
ViewStation.
Consult your network administrator.
Your PC is on a different 
subnet and there is router 
between you and your 
ViewStation.
Change your PC or ViewStation Subnet 
mask and IP address so that they are both on 
the same LAN or subnet.
System does not allow 
management via the web.
Wrong password.
Enter the correct password. Note: The 
default password is “admin”.
Too many managers logged 
into the system.
Only two system managers are allowed at 
any one time. To log everybody else out, 
restart your ViewStation.