Sony DXC-D35 User Manual
3-8
DXC-D35/D35WS(UC)
DXC-D35P/D35WSP(CE) V1
R
M
G
C
Y
G
Y
L
B
R
M
G
C
Y
G
Y
L
B
75%
100%
75%
Item
Test Point
Specification
Y LEV
TP61
NTSC: A = 714
±
10 mV
F = 54
±
5 mV
PAL:
A = 700
±
10 mV
*
W Y LEV
TP61
NTSC: A = 714
±
10 mV
PAL:
A = 700
±
10 mV
SYNC LEV
TP61
NTSC: B = 286
±
5 mV
PAL:
B = 300
±
5 mV
R-Y LEV
TP60
NTSC: C = 700
±
20 mV
PAL:
C = 525
±
20 mV
*
W R-Y LEV
TP60
NTSC: C = 700
±
20 mV
PAL:
C = 525
±
20 mV
B-Y LEV
TP62
NTSC: D = 700
±
20 mV
PAL:
D = 525
±
20 mV
*
W B-Y LEV
TP62
NTSC: D = 700
±
20 mV
PAL:
D = 525
±
20 mV
*
: DXC-D35WS/35WSP only
3-3-5. Carrier Balance Adjustment
Equipment:
Verctorscope (MAX GAIN)
Preparation:
OUTPUT/DL/DCC
+ switch: BARS
Test point:
VIDEO OUT connector
Adjusting point
1.
SERVICE menu “PAGE 7”
→
R-Y C/B
B-Y C/B
B-Y C/B
2.
Adjust by the UP switch or DOWN switch to
bring the beam spot of the black level in the center of
the vectorscope.
bring the beam spot of the black level in the center of
the vectorscope.
[for NTSC]
[for PAL]
B
A
(NTSC)
(PAL)
B
A
F
C
D
3-3. Camera Adjustment