Sony DXC-D35 User Manual

Page of 122
3-6
DXC-D35/D35WS(UC)
DXC-D35P/D35WSP(CE) V1
R
M
G
C
Y
G
Y
L
B
R
M
G
C
Y
G
Y
L
B
Burst
H
H
Burst
3-3. Camera Adjustment
n
Before the adjustment, enter the “PAGE 1” of SERVICE
menu, and perform the “RESET”.
3-3-1. Sub-Carrier Frequency Adjustment
Equipment:
Frequency counter
To be extended:
ES-32 board (for DXC-D35/D35P)
ES-33 board (for DXC-D35WS/D35WSP)
Test point:
TP501 (GND: E501)
/ES-32 board (for DXC-D35/D35P)
/ES-33 board (for DXC-D35WS/D35WSP)
Adjusting point:
SERVICE menu “PAGE 8”
 SC FREQ:
Adjust the sub-Carrier Frequency by
UP   switch or DOWN   switch to
meet the specification.
Specification:
3,579,545 
±
10 Hz (for NTSC)
4,433,618 
±
10 Hz (for PAL)
3-3-2. INT SC-H Phase Adjustment
n
Stated below is a procedure with the SC-H phase measur-
ing equipment (Tektronix Waveform monitor 1765).
If any other equipment is used, perform adjustment at the
following adjustment point by reading the instruction
manual attached.
Equipment:
Waveform monitor (SC-H Phase mode)
Preparation:
. Put the Tektronix Waveform monitor 1765 to SC-H
mode.
Test point:
VIDEO OUT connector
Adjustment Procedure
1.
SERVICE menu “PAGE 8”
 SC-H
2.
Adjust the phase relationship between SC (Burst) and
H beam spot correctly by UP   switch or DOWN 
switch.
[for NTSC]
[for PAL]
n
After this adjustment, set the mode of Tektronix Waveform
monitor 1765 to “WFM” mode.
3-3. Camera Adjustment
TP501
RV501
RV502
RV503
RV504
RV505
E501
FL502
CN501
1
2
3
4
5
6
A
B
C
D
ES-32 board (A side) (DXC-D35/D35P)
ES-33 board (A side) (DXC-D35WS/D35WSP)