Command List
Focus and Focus Distance (for reference)
Zoom Position
0000
to
4000
to
7AC0
 Wide end
Optical
Digital
Tele end
Tele end
Focus Position
1000 to F000*
Far end Near end
* Depending on the Focus Near Limit
setting.
Focus Near
Limit
1000: Over Inf
2000: 25 m
3000: 11 m
4000: 7 m
5000: 4.9 m
6000: 3.7 m
7000: 2.9 m
8000: 2.3 m
9000: 1.85 m
A000: 1.5 m
B000: 1.23 m
C000: 1 m
D000: 30 cm
(initial setting)
E000: 8 cm
F000: 1 cm
As the distance on the left
will differ due to
temperature
characteristics, etc., use as
approximate values.
* The lower 1 byte is fixed at
00.
Others
AF Active Time
1)
00
to
FF
AF Interval Time
1)
00
to
FF
R Gain
00
to
FF
B Gain
00
to
FF
Aperture Level
00
to
0F
NR Level
00
to
05
AutoICR ON 
OFF Threshold Level
00
to
1C
Chroma Suppress setting level
00
to
03
Color Gain setting level
00
to
0E
Color Hue setting level
00
to
0E
1)
Unit: One second
Pan/Tilt Status Code List
P
Q
R
S
- - - - - - - - 0 - - - - - - 1 A Pan movement all the way to the left
- - - - - - - - 0 - - - - - 1 - A Pan movement all the way to the right
- - - - - - - - 0 - - - - 1 - - A Tilt movement all the way up
- - - - - - - - 0 - - - 1 - - - A Tilt movement all the way down
- - - - - - - - - - 0 0 - - - - Pan movement is correct
- - - - - - - - - - 0 1 - - - - Pan position cannot be detected
- - - - - - 0 0 0 - - - - - - - The Tilt movement is correct
- - - - - - 0 1 0 - - - - - - - The Tilt position cannot be detected
- - - - 0 0 - - 0 - - - - - - - No movement instructions
- - - - 0 1 - - 0 - - - - - - - In the midst of a Pan/Tilt
- - - - 1 0 - - 0 - - - - - - - Pan/Tilt completed
- - - - 1 1 - - 0 - - - - - - - Pan/Tilt failed
- - 0 0 - - - - 0 - - - - - - - Not initialized
- - 0 1 - - - - 0 - - - - - - - Initializing
- -1 0 - - - - 0 - - - - - - - Initialization completed
- -1 1 - - - - 0 - - - - - - - Initialization failed
( - : optional)
Pan/Tilt Position (for reference)
Parameter (position)
PAN
E1E5 (–170 degree) to 1E1B (+170 degree)
TILT
FC75 (–20 degree) to 0FF0 (+90 degree)
(IMAGE FLIP: OFF)
F010 (–90 degree) to 038B (+20 degree)
(IMAGE FLIP: ON)
LED Status
Status
POWER (Green)
STANDBY (Orange)
Main power ON Power On (including initializing period)
On
Off
When receiving infrared signals form Remote Commander
Blinking
Off
At position detection error
On
Blinking
Standby status
Off
On
Power off by VISCA or the Remote Commander
Main power Off
Off
Off
Initialization 
error
Pan/tilt error
Blinking
Blinking
Internal error(LSI, etc.)
Blinking alternately
BOTTOM switch 
and SYSTEM 
SELECT switch
Setting error (Example: when the SYSTEM SELECT switch is set to
positions “4 - 6” or “C - F” for the EVI-H100V, or positions “5 - 6” or “D -
F” for the EVI-H100S.)
On
On
Cooling fan malfunction (camera images still output)
Blinking alternately (slow)