Pelco FR106011 User Manual

Page of 40
20
C2649M (9/07)
Table D.  Data Connector Pin Assignments
Pin 
Number
RS-232
RS-422
RS-485 
2-Wire
RS-485 
4-Wire
Manchester
Bi-Phase
1
TX+ (Out+)
T+/R+ (Out+/In+) TX+ (Out+)
TX+ (Out+) (W)  TX+ (Out+)
2
TX-(Out-)
T-/R-(Out-/In-)
TX- (Out-)
TX- (Out-) (B) 
TX- (Out-)
3
RX+ (In+)
RX+ (In+)
RX+ (In+) (W) 
RX+ (In+)
4
RX- (In-)
RX- (In-)
RX- (In-)  (B)   
RX- (In-)
5
RX  (In)
6
TX  (Out)
7 or 8
Ground
—*
—*
—*
Shield
Shield
*Ground may be required based on conditions of installation. Refer to the current version of EIA/TIA-422 
and EIA/TIA-485 standards for additional information.
NOTES:
TX (Out), TX+ (Out+), TX- (Out-), T+ (Out+), and T- (Out-) denote data output from the transmitter/
receiver.
RX (In), RX+ (In+), RX- (In-), R+ (In+), and R- (In-) denote data input to the transmitter/receiver.
W denotes white wire, and B denotes black wire.
Data ports are not terminated. For RS-422, RS-485 2-Wire, RS-485 4-Wire, Manchester, and 
Bi-Phase data signals, termination may be required based on conditions of installation. If 
termination is required, terminate the data signal at the endpoint of the data bus using a 120-ohm 
resistor.
Table E.  Audio Connector Pin Assignments
Pin Number
Balanced
Unbalanced
1
In,  Left+
2
In, Right+
3
In,  Left-
4
In, Right-
5
In,  Left
6
In, Right
7 or 8
Shield
9
Out, Left+
Out, Left
10
Out, Right+
Out, Right
11
Out, Left-
12
Out, Right-