Sony 510P User Manual

Page of 208
Cha
p
te
r 4  
 Sc
en
e Sele
c
tion
73
4-3 Clip List Operations
4-3-5 Clearing the Current Clip List
Proceed as follows to clear the current clip list, leaving it 
with no clip list loaded.
1
Select CLEAR in the CLIP menu, and press the SEL/
SET dial or the MENU knob.
The following screen display appears.
2
Press the SEL/SET dial or the Menu knob.
The message “EXECUTE OK? YES 
b NO” appears.
3
Turn the SEL/SET dial or the MENU knob to move the 
b mark to “YES” and press the dial/knob.
The current clip list is cleared, leaving it with no clip 
list loaded.
4
Hold down the SHIFT button and press the SUB CLIP 
button.
CLIP menu operations end.
4-3-6 Setting the Start Time code of 
the Current Clip List
The start time code (LTC) of the current clip list is set to 
00:00:00:00 when the camcorder is powered on and when 
a disc is inserted.
You can set the start time code to any value. Proceed as 
follows.
1
Select TC PRESET in the CLIP menu, and press the 
SEL/SET dial or the MENU knob.
The following screen display appears.
2
Turn the SEL/SET dial or the Menu knob to select the 
item (HOUR, MIN, SEC, or FRAME) which you want 
to set, then press the dial/knob.
3
Turn the SEL/SET dial or the Menu knob until the 
desired value is displayed, then press the dial/knob.
4
After all items have been set, select OK, and press the 
SEL/SET dial or the MENU knob.
The starting time code of the current clip list is set to 
the specified LTC value. The count starts from that 
value when playback starts.
5
Hold down the SHIFT button and press the SUB CLIP 
button.
CLIP menu operations end.
CLIP LIST CLEAR   ESC
 CLEAR CLIP LIST :  EXEC
CLIP LIST TC PRS  ESC
 HOUR
:    00
 MIN             :    00
 SEC             :    00
 FRAME           :    00
 OK