TE Connectivity LAN Cat.6 S/FTP 1-0959385-1 User Manual
Product codes
1-0959385-1
108-93010
Rev E
3 of 5
INGF-070
TRANSMISSION
Cat 6 Patch cord requirements
Return Loss
Return Loss
(1)
Cat 6 Return Loss cord requirements
according to ISO/IEC 11801 2
according to ISO/IEC 11801 2
nd
Edition
Amend. 2
IEC 61935-2, Paragraph 5.6
NEXT Loss
Cat 6 NEXT Loss cord requirements
according to ISO/IEC 11801 2
according to ISO/IEC 11801 2
nd
Edition
Amend. 2
IEC 61935-2, Paragraph 5.7
MECHANICAL
Crimping Height
Relevant IEC 60603-7-X standard
Indicator with needle-point probes or
equivalent. It shall be measured at the front
of the contact.
equivalent. It shall be measured at the front
of the contact.
Tensile Strength
Force applied: 50 N according to the
standard. Duration: 5 seconds
standard. Duration: 5 seconds
IEC 61935-2, Paragraph 6.2.
(See figure 3 as information)
(See figure 3 as information)
Torsion Force
(specified by Tyco
Electronics)
(specified by Tyco
Electronics)
Force applied: 10 N x cm
Duration: 5 seconds
Maximum Rotation angle 45º
Duration: 5 seconds
Maximum Rotation angle 45º
(See figure 4 as information)
NOTE
See Test Sequence in paragraph 4.2 Figure 6
Figure 1: Requirements and test procedures for Cat 6 shielded patch cords
REMARK
(1)
Return Loss values below 4MHz are for information only according to AMD2 to ISO
11801 2
11801 2
nd
Edition
Figure 2: AMPTRAC connection continuity and short-circuit test procedure
Figure 3: Tensile strength test procedure
Figure 4: Torsion force test procedure
Torque value to be applied between
shield and cable jacket
shield and cable jacket
cm
N
⋅
10
Maximum rotation
angle 45º
angle 45º
Maximum distance
between shield and
cable clamp 5mm
Test based on
1 rotation x 1 side