Lucent Technologies 555-670-111 User Manual

Page of 1082
MERLIN LEGEND Communications System Release 7.0
System Programming  
555-670-111  
Issue 1
April 1999
Prior Releases: Features and Enhancements 
xxxvii
Release 5.0 Enhancements (June 1997) 
The primary and secondary announcement options, when used together, allow an 
initial message to play for callers, followed by a repeating announcement that, for 
example, urges callers to stay on the line and wait for a calling group member.
Two or more groups may share an announcement device.
A primary delay announcement device can be programmed as a secondary delay 
announcement device.
Enhanced Calls-in-Queue Alarm Thresholds
0
Three Calls-in-Queue Alarm thresholds can be set to more clearly indicate the 
real-time status of the calls waiting in the queue according to the behavior of 
programmed Calls-in-Queue Alarm buttons. In earlier releases, only one Calls-in-
Queue Alarm Threshold setting is available to activate the LEDs at programmed 
Calls-in-Queue Alarm buttons for a calling group.
Using all three levels, the system manager sets Threshold 3 to the highest value, 
Threshold 2 to a middle value, and Threshold 1 to the lowest value. A 
Calls-in-Queue Alarm button indicates the severity of the alarm conditions in the 
following ways:
If the number of waiting calls is less than the value programmed for 
Threshold 1 or drops below that level, the LED is unlit.
If the number of waiting calls is greater than or equal to the Threshold 1 
value but less than the Threshold 2 value, the LED flashes.
If the number of waiting calls is greater than or equal to the Threshold 2 
value but less than the value for Threshold 3, the LED winks.
If the number of waiting calls is greater than or equal to the highest value, 
Threshold 3, the LED lights steadily. 
NOTE:
A Direct Station Selector (DSS) button that is used as a 
Calls-in-Queue Alarm button can only indicate two threshold levels, 
either by flashing or by lighting steadily. If a calling group must use 
this type of Calls-in-Queue Alarm button, only two threshold levels 
should be programmed.
If all three thresholds are set to the same value, the result is one threshold only 
with LED state either off or on (steady). If two values are the same, then the result 
is two alarm levels (flash, steady). The factory setting is one call for all three 
thresholds, with LED states of off and steady. 
An external alert signals only when the number of calls in the queue meets or 
exceeds the programmed Threshold 3 value.