9.4 
DSP 402 Homing Methods 
The following sub-sections describe the details of how each homing mode functions. The 
Elmo drives support each of these methods. 
9.4.1  Method 1: Homing on the negative limit switch and 
index pulse 
Using this method, the initial direction of movement is leftward if the negative limit 
switch is inactive (here shown as low). The home position is at the first index pulse to the 
right of the position where the negative limit switch becomes inactive. 
 
Figure  9-1: Homing on the negative limit switch and index pulse 
9.4.2  Method 2: Homing on the positive limit switch and 
index pulse 
Using this method, the initial direction of movement is rightward if the positive limit 
switch is inactive (here shown as low). The position of home is at the first index pulse to 
the left of the position where the positive limit switch becomes inactive. 
 
Figure  9-2: Homing on the positive limit switch and index pulse 
CANopen DSP 402 Implementation Guide 
 
MAN-CAN402IG (Ver. 1.2) 
 
 
60