  The speed is submitted to the maximum speed limit given by the user during 
setup. Otherwise, an abort message with abort code 0609 0030, “Value range of 
parameter exceeded” is activated. If the limits have been changed during the 
process, the drive enters a fault state. 
 
Object 0x609A: Homing acceleration  
This object establishes the acceleration to be used for all accelerations and decelerations 
with the standard homing modes, and is given in acceleration units. 
 
Object description: 
Index 609Ah 
Name Homing 
acceleration 
Object code 
VAR 
Data type 
UNSIGNED32 
Category Optional 
 
Entry description: 
Access Read/write 
PDO mapping 
No 
Value range 
UNSIGNED32 
Default value 
No 
  Home deceleration is performed according to the SD value set during setup. The 
user may use the binary interpreter to modify this value. Refer to the relevant 
Command Reference Manual for the SD parameter information. 
9.3 Functional 
Description 
Choosing a method of homing by writing a value to homing method clearly establishes the: 
 
Homing signal (positive limit switch, negative limit switch, home switch) 
 
Direction of actuation 
 
Position of the index pulse, where appropriate 
Homing is performed on either the main position sensor (PX) or the auxiliary position 
sensor (PY), depending on the unit mode — for position loop (UM=5) or dual loop 
(UM=4) — respectively. The relevant source is selected when homing is activated by the 
controlword
The home position and zero position are offset by the home offset (see the home offset 
definition for how this offset is used).