DMP Electronics XR10A User Manual

Page of 18
Installation
XR6A/XR10A/XR20A Installation Guide
Digital Monitoring Products
2841 E. Industrial Drive  Springfield, MO  USA  65802-6310  800-641-4282
Annunciator Outputs
12.1 Description
The four annunciator outputs can be programmed to indicate the activity of the panel's zones or conditions
occurring on the system. Annunciator outputs do not provide a voltage but instead switch to ground
voltage from another source.
 The outputs can respond to any of the conditions listed below:
1)  Activation by zone condition: Steady, Pulse, Momentary, or Follower
2)  Manually from the Security Command keypad
3)  Communication failure
4)  Armed area annunciation
5)  Fire Alarm or Fire Trouble
7)  Ambush alarm
8)  Exit and Entry timers
9)  System Ready
10)  Ground start activation
12.2 Harness wiring
The open collector outputs are accessible by installing the DMP 300 Harness on the 4-pin header labeled J11.
The output locations are shown below:
Output
Color
  Wire
1
Red
1
2
Yellow
2
3
Green
3
4
Black
4
Telephone RJ Connector
13.1 Description
Connect the panel to the public telephone network by installing a DMP 356 RJ Cable between the panel's J4
connector and the RJ31X or RJ38X phone jack.
Phone Cable Monitor
A two pin header labeled RJ SUP (J7) is provided to allow monitoring of the telephone cable connected between
the panel and a RJ38X jack (pins 2 & 7 jumpered). Attach a DMP Model 306 Harness between J7 and any
available zone. The pins of J7 are connected via the telephone cable to 2 & 7 of the RJ38X jack. The RJ38X jack
provides a jumper between pins 2 & 7 which completes the circuit.
When the zone is programmed for a Supervisory type (SV) and the telephone cable is removed, the keypad will
display the zone in trouble and produce a steady tone.
13.2 ACA Compliance
The XR6A/XR10A/XR20A have been tested and meet the requirements of ACA Technical Standard
TS-002-1997 for Telecommunications.
13.3 Ground start
To configure the XR6A/XR10A/XR20A for ground start operation, you must install the appropriate ground start
module and program one of the panel's available annunciator outputs for Ground Start operation. Refer to the
XR6A/XR10A/XR20A Programming Guide for complete programming information.
Page 12