Introduction
XR6A/XR10A/XR20A Installation Guide
2841 E. Industrial Drive  Springfield, MO  USA  65802-6310  800-641-4282
Digital Monitoring Products
System Components
3.1
Description
The DMP XR6A/XR10A/XR20A system is made up of an alarm panel with built in communicator, an enclosure, a
16.5 VAC transformer, and a 12 VDC 7.0 Ah battery. You can add up to four Security Command keypads to the
system and can also connect auxiliary devices to the panel's open collector outputs to expand the basic system.
Combined current requirements of additional modules may require an auxiliary power supply. Refer to section 6.6 in
this guide when calculating power requirements. In addition, up to 16 points of zone expansion can be added to the
XR20A and four points to the XR6A.
3.2
Wiring diagram
The XR6A/XR10A/XR20A system wiring diagram in Figure 1 shows some of the accessory devices you can
connect for use in various applications. A complete description of each module follows. Zone expanders can be
added to the XR6A or XR20A.
3.3
Lightning protection
Metal Oxide Varistors and Transient Voltage Suppressors help protect against voltage surges on input and output
circuits. A transorb is provided for the Smoke Detector Output Circuit (Terminal 11). This transient protection
provides additional resistance to electrical surges such as lighting. Additional surge protection is available by
installing the DMP 370 or 370RJ Lightning Suppressors.
3.4
Command Processor Accessories
You can connect any combination of up to four Model 670, 770, and 771 vacuum fluorescent, 690, 790, 791, and
793 LCD, or 692 LED Security Command Keypads to the 4-wire keypad data bus provided by the panel on
terminals 7, 8, 9, and 10. Also, you can connect Model 714, 715, 714-8, 714-16, 715-8, 715-16 zone expanders
to the XR20A or XR6A 4-wire keypad bus. (Note: The XR10A does not support zone expansion on the keypad
bus.)
Page 3