Panasonic AW-HE120KP User Manual

Page of 100
27
Adjustment
 Black level (master pedestal) adjustment
(continued)
When performing the operations using the controller
When the AW-RP655 is connected:
Press the [IRIS] button several times to turn off 
its lamp.
Set the iris to the manual ([MANU]) mode.
Turn the [FOCUS/IRIS] dial to stop down the 
lens iris.
Press the [R/B GAIN/PED] button several 
times so that the “PEDESTAL TOTAL” item is 
displayed on the LCD panel.
Turn the jog dial (main) and adjust the black 
level to 0.035 V.
If necessary, adjust the iris automatically.
  Press the [IRIS] button several times to turn on its 
lamp.
When the AW-RP555 is connected:
Press the [IRIS] button several times to turn off 
its lamp.
Set the iris to the manual ([MANU]) mode.
Turn the [LEVEL] dial of [IRIS] to stop down the 
lens iris.
Follow the operation steps in “Basic 
operations” (page 35), and use the camera 
menu to perform the adjustment.
When the AW-RP50 is connected:
Refer to the Operating Instructions of the controller.