ENFORCER Delayed Egress Timer 
 
 
SECO-LARM U.S.A., Inc                                                                                      5
 
SECO-LARM U.S.A., Inc.                                                                                                   
               33                                              5                                                                                         
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
IMPORTANT 
Users  and  installers  of  this  product  are  responsible  for 
ensuring  that  the  installation  and  configuration  of  this 
product  complies  with  all  national,  state,  and  local  laws 
and  codes  related  to  locking  and  egress  devices.  
SECO-LARM will not be held responsible for the use of 
this product in violation of any current laws or codes.  
Relock Modes: 
Standard Mode (Default) 
The SA-025EQ can operate in three different 
relock modes: standard modeBOCA 
mode
, and timed mode. In order to switch 
between these modes, locate the relock 
mode jumper on the circuit board and move 
the jumper to the appropriate pins. 
Relock mode 
jumper 
Once the lock has been released, it will remain released until manually relocked by a reset 
device connected to the Reset Input. For information on connecting a reset device, see pg. 4, 
Wiring Diagram. This reset device is often a momentary spring-loaded key switch. 
BOCA Mode 
This mode is for use with BOCA (Building Officials Code Administrators) regulations.  
Once the lock is released, the door will remain unlocked until the door is closed. Once closed, the 
door will still remain unlocked for 30 seconds. If the door is opened at any time during the 30 
seconds, the timer will reset. The 30-second timer will restart once the door is closed.  
NOTE: The lock status jumper (see pg. 7) must be ON with a door-mounted N.C. magnetic contact 
connected to the lock status input terminal for the BOCA mode to operate correctly. 
Timed Mode 
Once the lock is released, it will remain released for the duration of the set post-delay timer.  
To set the post-delay timer see pg. 6, Adjusting the Pre-Delay and Post-Delay
Standard mode 
BOCA mode 
Timed mode