SECO-LARM USA SA-025EQ User Manual

Page of 12
ENFORCER Delayed Egress Timer 
 
 
SECO-LARM U.S.A., Inc                                                                                      7
 
SECO-LARM U.S.A., Inc.                                                                                                   
               33                                              7                                                                                         
 
 
 
Lock Status Jumper: 
 
When the lock status jumper is ON, the lock status 
input will detect whether the door is closed and will 
trigger relock functions. 
 
The lock status input may be bypassed in order to 
keep the door unlocked for an indefinite period of time 
without activating the remote alarm output. 
 
To bypass the lock status input, set jumper 1 to OFF. 
 
The lock status input must be ON for BOCA Mode 
(See pg. 5, Relock Modes). 
Jumper 1 
Jumper 2 
Jumper 3 
Default: OFF 
Default: OFF 
 
The SA-025EQ is equipped with a 500mA@12VDC 
transistor ground output for a local alarm, typically an 
audible or visual device. 
 
The local alarm output can be set for steady or 
pulsing. When set ON, the local alarm pulses during 
the pre-delay, gradually pulsing faster until the end of 
the pre-delay time. The local alarm will continue 
signaling steady 5 seconds after the lock has been 
released. When set OFF, the local alarm is steady 
during the pre-delay time and for 5 seconds after the 
lock has been released. 
 
LED 4 is on when the local alarm output is active. 
 
The local alarm signals when the pre-delay bypass  
is used (see pg. 9). 
 
To set the local alarm output type ON (steady) or 
OFF (pulsing), use jumper 3 on the right side of the 
circuit board. 
Local Alarm Output Type Jumper: 
Security Mode Jumper: 
 
To activate security mode, set jumper 2 to ON. 
 
In security mode, after the initiate device (such as a 
push-to-exit bar) has been triggered and the  
pre-delay timer has ended, the lock will remain active 
until the initiate device has been triggered a second 
time. 
 
When security mode is OFF, the initiate device must 
only be activated once. 
 
Default: OFF