Avaya 03-300430 User Manual

Page of 2574
DS1-BD (DS1 Interface Circuit Pack)
Issue 1 June 2005
1037
 
2
FAIL
The CLJ-LB test failed because it was not set up properly. The DS1 
interface pack could not successfully put the CPE loop-back jack into 
loop-back mode.
1. Rerun test ds1-loop location 
cpe-loopback-jack-test-begin.
2. If the test continues to fail, the problem could be with the TN767E 
board, the CPE loop-back jack equipment, or somewhere between. 
Run test ds1-loop location ds1/csu-loopback-tests to 
determine if the loop-back tests that are closer to the TN767E board 
are successful. If any of the tests fail, follow the maintenance strategy 
that is associated with the failing test.
3
FAIL
The CPE Loopback Jack test was not set up properly. The framed 3-in-24 
test pattern, generated by the DS1 Interface circuit pack and looped back 
through the CPE loop-back jack, could not be detected properly by the DS1 
circuit pack.
1. Retry test ds1-loop location 
cpe-loopback-jack-test-begin.
2. If the CPE Loopback test continues to fail, the problem could be with 
the TN767E board, the CPE loop-back jack equipment, or somewhere 
in between. Run test ds1-loop location ds1/
csu-loopback-tests
 to see if the loop-back tests closer to the 
TN767E board are successful. If any of those loop-back tests fail, 
follow the maintenance strategy associated with those.
 
PASS
The CPE Loopback Jack test has successfully began executing. The test 
runs until the system technician enters the test ds1-loop location 
end-loopback/span-test or release board location.
Table 356: Test #1212 CPE Loopback Jack Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 4