Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
1154 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each appropriate test’s description, and follow its recommended 
procedures.
b. Error Type 1: Ethernet Local Looparound test (#1278) failed.
1. Test the port (test port location long).
2. Refer to repair procedures for Test #1278.
c. Error Type 513: Link Integrity Inquiry test (#1282) failed, or C-LAN port detected loss of 
Ethernet link integrity.
Possible causes:
Cables
Ethernet transceiver
1. Test the port (test port location long).
2. If the Link Integrity Inquiry test (#1282) fails, refer to its repair procedure.
Table 395: ETH-PT Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0 (
0
Any
Any
Any
test port location s
1 (
0
Ethernet Local Looparound test 
(#1278)
MIN
ON
test port location l r 3
513 (
0
Link Integrity Inquiry (#1282)
MIN
OFF
test port location r 2
769 (
0
WRN
OFF
1281 (
0
1537, 
1538 (
)
Session Status test (#1286)
MIN
OFF
1793–
1920 (
2305–
2560 (
2561–
2816 (
3329 (
TCP/IP Ping test (#1281)
WRN