Avaya 03-300430 User Manual

Page of 2574
Server Alarms
120 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
S8500B Augmentix Server Availability Management Processor™ 
(A+SAMP) Alarms   
S8500B Only
The Augmentix Server Availability Management Processor (A+SAMP) board is installed in the 
S8500B media server. It monitors and reports alarms on S8500B components and software and 
provides control to power on and power off the server.
The A+SAMP will report alarms when it detects certain failure conditions. See 
Maintenance Object (MO) name RMB. These alarms will be reported with a Product ID 
beginning with a five (5) and followed by nine digits.
The S8500 media server may also report failure conditions via the MO name RMB but these 
alarms will have a Product ID that begins with a one (1) followed by nine digits. See 
Table 35: A+SAMP Alarms in the S8500B Media Server
Event
ID
Alarm
Level
Alarm Text, Cause/Description, Recommendation
0
MIN
Test Alarm. Hardware Platform Interface (HPI) User Event
1
MIN
Loss of power to host. Hardware Platform Interface (HPI) Sensor Event. 
2
MAJ
Host boot timeout. Hardware Platform Interface (HPI) OEM Event
3
MAJ
Host Alarm. Hardware Platform Interface (HPI) User Event
4
MIN
Loss of External Power to SAMP. Hardware Platform Interface (HPI) 
Sensor Event
5
MAJ
Host failure timeout. Hardware Platform Interface (HPI) Watchdog Event