Avaya 03-300430 User Manual

Page of 2574
IPMEDPRO (TN2602AP IP Media Resource 320)
Issue 1 June 2005
1383
 
Notes:
a. Error Type 1: the circuit pack has been removed from the system or is not fully 
administered. The alarm is logged about 15 minutes after the circuit pack has been 
removed, or 11 minutes after the SAKI test (#53) fails.
To be fully administered, an IP Media Resource must:
Have an entry on the circuit pack screen (change circuit-pack)
Have the Media Resource IP address administered (change node-names)
Be enabled (change ip-interface)
Be physically inserted into the correct slot
If the circuit pack has an entry on the circuit pack screen and any of the other conditions are 
not met, a MINOR alarm is logged. To resolve the error:
Make sure every condition for administration is met, and that a functioning Media 
Resource is inserted in the correct slot.
Completely remove the IP Media Resource from the system:
a. Remove the administered IP-Interface associated with the circuit pack.
3073 (
)
Any
Aggregator 
Hardware Query 
(#1629)
MIN
ON
3329 (
)
Any
Duplicate 
network IP 
address detected
(#1371)
MIN
OFF
3585 (
)
1 or 2
Verify NIC option 
test (#1511)
MIN
OFF
 3841(
None
Inconsistent 
downlink or 
board error
 3841(
4283
RTCP Monitor 
Server error
3999 (
Any
None
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each 
appropriate test’s description, and follow its recommended procedures.
2. Minor alarms on this MO may be downgraded to warning alarms based on values set in set options.
Table 485: TN2602AP IP Media Resource Maintenance Error Log Entries  (continued)
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
 3 of 3